Configure the redundancy behaviour to automatically switch stream inputs in case of a failure.
The integrated analyzer continuously monitors the active input, and if a fault is detected, it immediately switches to an alternate input.
The default behavior is Active Backup. In the event of a failure, Astra switches to the next input while continuing to analyze the previous inputs for a potential switch back.
If all inputs fail, Astra will continue to stream latest avilable input. To halt streaming, an additional option is available for the Backup Type: "Active Backup and Stop streaming if all inputs are inactive"
In the event of a failure, Astra switches to the next input and stops the previous input. If the last input fails, Astra will automatically switch back to the first input
In the event of a failure, Astra does nothing. This method is suitable for manually switching inputs using the Web Interface or API methods.
Read more in Stream API > Switch active input